PANASONIC M1S SERIES PANASONIC M1G SERIES PANASONIC M1D SERIES
M1S Series M1G Series M1D Series
PANASONIC M1X SERIES    
M1X Series    

 

M1X Series

Specification

*1. Please select the proper motor which does not exceed the rating of the inverter.

*2. Rated capacity is a value of 460V of the rated output voltage.

*3. The output voltage of the inverter will not exceed the power source voltage.

  Part Number M1X084BSA M1X154BSA M1X224BSA M1X374BSA
Applicable motor (kW)-1 0.75 1.5 2.2 3.7
Output capacity (kVA)-2 2.0 3.0 4.4 7.2
Output current (A) 2.5 3.7 5.5 9.0
Output voltage -3 3-phase power source  :  3-phase AC 380 to 460 V
Input Voltage 3-phase power source  :  3-phase AC 380 to 460 V
Frequency 50/60Hz
Voltage fluctuation allowance -15%, + 10%
Frequency fluctuation allowance 0.5%
Control method Low noise sine wave PWM
Output frequency 0.5 to 400 Hz (Start from 0.05 Hz)
Frequency accuracy 0.5% (25C 10C
Frequency setting resolution
  • Digital : 0.01 Hz
  • Analog : Setting frequency range/1000 Hz (minimum 0.05 Hz)
Frequency setting signal DC 0 to + 5V, 0 to + 10V, 4 to 20 mA
Voltage/Frequency characteristics Base frequency : 30 to 400Hz (1 Hz step) with reduced torque pattern
Rated overload current 150%/min
Regenerative brake torque 150% and avove 100% and above 70% and above
DC brake Brake start frequency/break operating time/break volume
Acceleration/deceleration time 0 to 3600 s(seconds)
(0 to 3s: 0.01s step, 3 to 10s step, 10s or more : 1s step)
*Adjustable for 4 kinds of acceleration/deceleration speeds up to 50Hz
Jogging frequency 0 to 30 Hz
Operation mode 2-speed, 4-speed, 8-speed, 16-speed
Others Auto boost, vector drive control, AVR function/retry function
RS-485 communication (factory-set option), parameter lock
Protective functions Under voltage protection, Over-current protection,
Over-voltage protection, Instantaneous power failure protection,
Stall prevention, Over-load limitation (current limiter), Overload trip (eletric thermal relay), Restart preventation when power is restored, Self-diagnosid trip (the last 5 causes of trips are saved)
Temperature -10C~+50C (Non-freezing) Remove the ventilation cover and rubber duct when temperature exceeds 40C
Relative humidity Relative humidity below 90% (Non-condensing)
Atmosphere Indoors (to be free from corrosive gas and dust)
Altitude Below  1000m
Vibration Below 5.9M/s2 (0.6G) (10~60Hz)
Enclosures Enclosed type (IP40) (with ventilation)
Cooling Method Self-cooling Fan-cooling
Mass (kg) 2.9

 

 